    Dawn HartAug 5, 2025
    Why am I getting a DC link overvoltage alarm on my gefran ADV200 WA DC?
    • J
      Jane JacksonAug 6, 2025
      A DC link overvoltage alarm may occur because the voltage arriving at the drive power section is related to the PAR 560 Mains voltage. To resolve this, you can try the following: * Extend the deceleration ramp. * Use a braking resistor between terminals. * Use the VDC Control function.

gefran ADV200 WA DC Series Specifications

General IconGeneral
Control ModeArmature voltage
Field RegulatorIntegrated
CommunicationModbus RTU
ProtectionOvercurrent, overtemperature, overvoltage, undervoltage, field loss
Operating Temperature0°C to +40°C
Humidity< 95% non-condensing