121
MAINTENANCE
Every 1000 Hours
8. After cleaning is completed, tighten the
drain plug (4) and add new coolant up to
the specified level.
9. Run the engine at a low idle, bleed the air,
then stop the engine once the coolant level
stabilizes at the specified level.
10. Check the coolant level, then tighten the
radiator cap (3).
11. Clean the inside of the reserve tank (1),
then add coolant up to the upper limit (H).
Replacing the Air Cleaner
Elements
WARNING
Stop the engine and allow the machine
to cool down before performing
maintenance.
¡¡
¡¡
¡The engine, muffler, radiator and many
other parts of the machine are hot
directly after the engine is stopped.
Touching these parts will cause burns.
IMPORTANT: Do not use an element if its
flutes, gaskets or seals are damaged.
1. Open the engine hood.
2. Loosen the clamp (1) and remove the dust
cup (2).
3. Clean the inside of the dust cup (2).
4. Remove the outer element (3).
Do not yet remove inner element (5).
5. Clean the inside of the body (4).
6. Remove the inner element (5).
7. Install the new elements.
8. Install the dust cup (2) with the TOP mark
at the top, then fasten it with the clamp (1).
4
3
2
5
1
T7G019