GEMAŞ Genel Mühendislik Mekanik San.ve Tic.A.Ş.
İTOB Organize Sanayi Bölgesi 10001 Sok.No:28 Menderes/İZMİR TURKEY
Tel:0232 799 0 333 Fax:0232 799 0 330 www.gemas.com.tr info@gemas.com.tr
ENG GEMAŞ STEAM GENERATOR AND CONTROL PANEL INSTRUCTIONS MANUAL V2.1
Time Date Settings
It is the page where the date and time settings of the device are made. The OK button is
pressed once to enter the page, and to exit the page, the RETURN button must be pressed once.
In the device setup, the current time is set, the clock continues to operate even if the power is cut
off as long as the clock battery is full.
When the setting page is entered, WEEK OF THE WEEK - MONTH OF THE MONTH - MONTH
- YEAR - HOUR and MINUTE parameters are displayed respectively. Parameter value is changed
by UP and DOWN direction buttons. When the desired value is given, it is selected and saved with
the OK button and automatically switches to the next parameter. Respectively, all parameters are
set and selected and saved with the OK button.
Heat Settings
It is the page where the temperature settings of the steam room are made. The OK button is
pressed once to enter the page, and to exit the page, the RETURN button must be pressed once.
When the setting page is entered, ISI SET. and HEAT TOL. parameters are displayed
respectively. Parameter value is changed by UP and DOWN direction buttons. When the desired
value is given, it is selected and saved with the OK button and automatically switches to the next
parameter. Respectively, all parameters are set and selected and saved with the OK button.
Current Settings
The device can be adjusted for power consumption between 6 kW and 18 kW. These power
consumptions can be adjusted by changing the current setting. The current can be adjusted from
5A to 15A. The OK button is pressed once to enter the page, and to exit the page, the RETURN
button must be pressed once.
CURRENT SET. and CURRENT TOL. parameters are displayed respectively. Parameter value
is changed by UP and DOWN direction buttons. When the desired value is given, it is selected and
saved with the OK button and automatically switches to the next parameter. Respectively, all
parameters are set and selected and saved with the OK button.
Working Hour Settings
Working hours settings are scheduled for weekly working hours. Press OK button once to enter
the page, and to exit the page, RETURN button must be pressed once.
DAY - ON - OFF - D parameters are displayed when entering the setting page. Parameter
value is changed by UP and DOWN direction buttons. When the desired value is given, it is
selected and saved with the OK button and automatically switches to the next parameter.
Respectively, all parameters are set and selected and saved with the OK button. If the arrow
symbol displayed on the screen is under any parameter, its adjustment is made with the UP and
DOWN direction buttons. The number under the parameter indicated by 'D' has 2 options, 0 and 1.
It operates according to the hours entered in position 1 and shuts down. In the 0 position, the
hours entered on that day of the week are ignored. Manual operation can be switched off that day.