GEMAŞ Genel Mühendislik Mekanik San.ve Tic.A.Ş.
İTOB Organize Sanayi Bölgesi 10001 Sok.No:28 Menderes/İZMİR TURKEY
Tel:0232 799 0 333 Fax:0232 799 0 330 www.gemas.com.tr info@gemas.com.tr
ENG GEMAŞ STEAM GENERATOR AND CONTROL PANEL INSTRUCTIONS MANUAL V2.1
COMMISSIONING AND USE
Review the electricity, water, drain and steam installations. Be sure to follow the assembly
instructions written above correctly. If there is no deficiency or error, you can start the
commissioning process.
Open the water valve. Make sure there are no water leaks at the valve and device inlets.
Make sure that the phases, neutral and ground wires are properly connected. Open the residual
current relay / fuse. Check the supply terminals with the control pen or gauge. Touch the
neutral and ground terminal blocks together with a cable. The leakage current relay must cut
off electricity. If there is no electricity cut, the leakage relay is defective or the grounding line is
weak. If this is the case, check the ground line, replace the residual current relay with a new
one and test again.
Turn on the device using the on / off switch on the front of the device. The control screen on
the front of the device will be energized. There will be a closed mode screen on the control
screen. Since the device is at the factory settings, it is necessary to set the operating time,
operating mode and operating time parameters according to the usage mode via the settings
menu.
At the factory, the generator is set to operate at 14A current 2A current tolerance, 45 ° C room
temperature and 5 ° C tolerance. If you want to change these settings, you can make the
necessary changes with the help of the User Guide.
When the settings are made and the device is started, the steam room will come to the set
temperature after a while (it may change between 10 minutes and 30 minutes) according to
the volume of the steam room. During this waiting period, observe both the entire installation
and the parts inside the generator.
Make sure that there are no water or steam leaks in the installation. If you detect any water or
steam leakage in the generator, immediately turn off the device from the fuse and check the
mechanical connections. If necessary, contact the manufacturer or service.
EVERY KIND OF CHANGES THAT CAN BE DONE ABOUT THE OPERATION OF THE DEVICE IS
DESCRIBED IN DETAILED USE MANUAL.
CLEANING AND MAINTENANCE INSTRUCTIONS
If you want to use GEMAŞ Steam Generator without any problems for years, make sure to
follow the cleaning and maintenance instructions written below completely and correctly. Please
keep in mind that the periodic maintenance and cleaning of the steam generator, which is not done
in a timely and complete manner, is the operating costs (expenditures for maintenance, electricity,
water consumption), times and times more than the costs of the device, which is maintained on
time and in accordance with the instructions. Do not ignore that the steam generator, whose
maintenance and boiler cleaning is not done on time, may always pose safety risks.