ENG GEMAŞ STEAM GENERATOR AND CONTROL PANEL INSTRUCTIONS MANUAL V2.1
Factory Settings
Heat Setting :45°C 10°C – 60°C
Heat Setting Tolerance :5°C 1°C – 5°C
Working Current :14A 5A – 15A
Working Current Tolerance :2A 1A – 5A
Working Hour Settings : When it is reset to factory settings, the working time
is 00:00 - 00:00. To run in automatic mode, a weekly schedule is required again.
Working mode : Manual
Operation time : 10min
Aroma Time : OFF(MİN)=10 – ON(SEC)=1 – D=0
Sediment Time : OFF(MİN)=5 – ON(SEC)=10 – D=1
Language : English
TECHNICIAL SPECIFICATIONS
Inlet Water Pressure : 1 Bar – 8 Bar
Inlet Water Temperature : +5°C – +55°C
Inlet Water Hardness : Between 0dh - 20 dh must be between German or s
0 fh - 35 fh French hardness.
Inlet Water Conductivity : Water conductivity must be between 100
microSiemens / cm and 1000 microSiemens / cm at 20 ° C water temperature.
Supply Cable : 5x4mm²
Leakage Relay : 4x25A / 30mA CE certified