DN 100 "T"
GB
INSTALLATION, OPERATING AND
MAINTENANCE INSTRUCTIONS
Diaphragm valve
Metal, DN 4 - 100
Actuator version "T" Actuator version "D"
Membranventil
Metall, DN 4 - 100
DE
ORIGINAL EINBAU- UND MONTAGEANLEITUNG
Antriebsausführung "T" Antriebsausführung "D"

Table of Contents

Questions and Answers

  • A
    Angela SteeleAug 12, 2025
    What to do if Gemu Control Unit valve doesn't open or doesn't open fully?
    • M
      mgarciaAug 13, 2025
      If the Gemu Control Unit valve doesn't open fully, consider these possible causes and solutions: * If the control pressure is too low (for control function NC), operate the valve with the control pressure specified in the data sheet. * If the pilot valve is faulty, check and replace it. * If the actuator is defective, replace it. * If the control medium is not connected, connect it. * If the shut-off diaphragm is incorrectly mounted, remove the actuator, check the diaphragm mounting, and replace it if necessary. * If the actuator spring is faulty (for control function NO), replace the actuator.
  • S
    Samantha StewartAug 20, 2025
    What to do if Gemu Control Unit valve leaks between actuator and valve body?
    • M
      Michael McdonaldAug 20, 2025
      If the Gemu Control Unit valve leaks between the actuator and valve body, consider the following possible causes: * The shut-off diaphragm might be incorrectly mounted. Remove the actuator, check the diaphragm mounting, and replace it if necessary. * The bolting between the valve body and actuator might be loose. Retighten the bolting. * The shut-off diaphragm might be faulty. Check the shut-off diaphragm for potential damage, and replace it if necessary. * The actuator or valve body might be damaged. Replace the actuator or valve body.
  • N
    newmanmatthewAug 25, 2025
    What to do if Gemu Control Unit valve body connection to piping leaks?
    • D
      David ChenAug 25, 2025
      If the Gemu Control Unit valve body connection to piping leaks, it could be due to: * Incorrect installation. Check the installation of the valve body in the piping. * Loose unions or threaded connections. Tighten the unions or threaded connections. * Faulty sealing material. Replace the sealing material.
  • J
    Joanna BellAug 28, 2025
    Why control medium escapes from leak detection hole in Gemu Control Unit?
    • A
      Amanda MortonAug 28, 2025
      If control medium escapes from the leak detection hole in your Gemu Control Unit, it is likely due to a leaking spindle seal. Replace the actuator and check the control medium for impurities.
  • D
    Denise HowellSep 1, 2025
    What to do if Gemu Control Unit valve body leaks?
    • C
      clopezSep 1, 2025
      If the Gemu Control Unit valve body leaks, it may be due to a faulty or corroded valve body. Inspect the valve body for potential damage, and replace it if necessary.
  • M
    meghangonzalesSep 4, 2025
    Why control medium escapes from vent hole/vent in the actuator cover for control function NC or connector 2 for control function NO in Gemu Control Unit?
    • S
      Stephen JonesSep 4, 2025
      If control medium escapes from the vent hole/vent in the actuator cover for control function NC or connector 2 for control function NO, it could be because the piston is faulty. Replace the actuator.
  • J
    Jason LoveSep 8, 2025
    What to do if working medium escapes from leak detection hole in Gemu Control Unit?
    • A
      Anthony JohnsonSep 8, 2025
      If the working medium escapes from the leak detection hole, the shut-off diaphragm might be faulty. Check the shut-off diaphragm for potential damage, and replace the diaphragm if necessary.
  • S
    stephen10Nov 15, 2025
    What to do if Gemu Control Unit valve leaks downstream (doesn't close or doesn't close fully)?
    • C
      Cheryl ScottNov 16, 2025
      If the Gemu Control Unit valve leaks downstream, consider these possible causes and solutions: * If the operating pressure is too high, operate the valve with the operating pressure specified in the datasheet. * If the control pressure is too low (for control function NO and control function DA), operate the valve with the control pressure specified in the data sheet. * If there is foreign matter between the shut-off diaphragm and valve body weir, remove the actuator, remove the foreign matter, and check the diaphragm and valve body weir for potential damage; replace if necessary. * If the valve body weir is leaking or damaged, check the valve body weir for damage and replace the valve body if necessary. * If the shut-off diaphragm is faulty, check the shut-off diaphragm for pot...

Summary

General Safety Information

Information for Service and Operating Personnel

Guidance for personnel involved in commissioning, operation, and maintenance of the valve.

Intended Area of Use

Technical Data

Functional Description

Installation and Operation

Installing the Diaphragm Valve

Step-by-step guide for installing the diaphragm valve into piping systems.

Control Functions

Description of available control functions like Normally Closed, Normally Open, and Double Acting.

Fitting;Removing Spare Parts

Mounting the Diaphragm

General guidelines and important notes for correctly mounting the diaphragm.

Commissioning

Inspection and Maintenance

Cleaning and Sterilization

Disassembly

Troubleshooting; Fault Clearance

Sectional Drawings and Spare Parts

Gemu 650 Specifications

General IconGeneral
Supply voltage24 V DC
Protection classIP 65
Model650
Housing materialPlastic
Operating Temperature-10°C
MediaInert