EasyManuals Logo

Generac Power Systems 5735 User Manual

Generac Power Systems 5735
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
Section 2 Engine DC Control System
Diagnostic Repair Manual 17
Fault Shutdown
With the generator running, if the low oil pressure (LOP) closes, wire 86 will be connected to wire 0 (frame ground).
Printed circuit board action will open wire 229 from ground; this action will de-energize the start stop relay (SSR). This
action will cause a shutdown.
004579

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems 5735 and is the answer not in the manual?

Generac Power Systems 5735 Specifications

General IconGeneral
BrandGenerac Power Systems
Model5735
CategoryPortable Generator
LanguageEnglish

Related product manuals