WALRUS 5000C
Page | 18
TROUBLESHOOTING
Fault codes will be displayed on the timer.
Press the P key in the heating mode. The fault code
will be displayed as XEXX, where X is the breakdown
number and XX is the fault code (see next page).
Use the arrow keys to view the breakdown
information.
To eliminate the failure information; hold
down the P key and press the heating button. The
information will now be cleared. Press the heating
button again to display the current time.
Treatment of usual troubles If the heater
is switched on but does not work correctly, the
following methods can be used for treatment.
Turn off and then restart the heater. Do not restart the heater
more than twice if the same problem persists.
Ensure that the heater has cooled completely before attempting
a restart, paying close attention if the coolant temperature
has exceeded 70°C.
Check the fuses
Ensure that there is sufficient coolant in the system before
starting-up, and never start the heater if the coolant has
frozen.