M02 Digital Indicator
30
F2.5
HiLo
MODBUS dual-byte register storage turn ,Hi Lo :
High byte in the front, low byte at the back;Lo Hi:Low
byte in the front, high byte at the back
F2.6
nonE
Cont mode automatic sending time interval
F2.7
0
tt(TOLEDOcontinuous mode)If send the checksum。
0:not send, 1:send.
F3
Null
The third major term of working parameter.
(For analog output only)
F3.1
0-5
Analog output:
4-20:4-20mA
0-20:0-20mA
0-24:0-24mA
0-5: 0-5V
0-10: 0-10V
I_out:Current customized
V_out:Voltage customized
In customized mode,F3.2-F3.5 parameters available
F3.2
3920
Minimum output
F3.3
4000
Zero point output