EasyManua.ls Logo

General Measure M02 - Analog; Digital

General Measure M02
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M02 Digital Indicator
4
1.3.2 Analog:
Load cell power: DC5V 200mAMAX
Input impedance: 10MΩ
Zero steady range: 0.0012mV(Load cell 3mV/V)
Input sensitivity: 0.1uV/d
Input range: 0.0015mV(Load cell 3mV/V)
Transfer mode: Sigma - Delta
A/D conversion speed: 15, 30, 60, 120, 480, 960 times/sec
Non-linearity: 0.01% F.S
Gain drift: 10PPM/
Display Precision: 1/100,000
1.3.3 Digital:
Weight display: 6 digits red high-brightness LED
Minus display: -”
Overload display: OFL”
Decimal point: 5 kinds (optional)
Function keys: 4 keys soniferous keypad