EasyManua.ls Logo

General Measure M02 - 6.6 rEREAD

General Measure M02
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M02 Digital Indicator
51
2bits
2C
47 53
2C
2B/2D
7bits
6B 67
0D
0A
Here:
Status —— 2 bitsOL(OFL):4FH 4CH; ST(stable):53H 54H; US(unstable):55H 53H
Display value —— 7bits, including decimal point, high bit is blank if no decimal point.
For example: When indicator send the following automatically:
53 54 2C 47 53 2C 2B 30 31 31 2E 31 32 30 6B 67 0D 0A
MeansStableData value is positivedisplay value is 11.120kg
6.6 rEREAD
Indicator will send weighing data to the upper computer under command.
Data format
Data
R
E
A
D
CR
LF
explain
52H
45H
41H
44H
0DH
0AH
The return data frame is the same with that of rECont protocol, please refer to rECont.
1) Zero clearing command: ZERO ON<CR><LF> : 5A 45 52 4F 20 4F 4E 0D 0A
Return YES<CR><LF> or NO? <CR><LF>