EasyManua.ls Logo

General Measure M02 - 6.3 tt TOLEDO Protocol

General Measure M02
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M02 Digital Indicator
48
that the check code is 38,34 for the data frame.
6.3 tt TOLEDO Protocol
When choose “tt” protocol in working parameter F2.3, indicator will send datas in
continuous mode with TOLEDO protocol.
Continuous sending mode format as below:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
STX
0D
︸ A B C display weight(6 bits) 6 个 30H Checksum
Here:start character is standard ASII start character 02(STX)
status byte A definition as below:
D0
0
1
0
1
0
D1
1
1
0
0
1
D2
0
0
1
1
0
Decimal point
x
.x
.xx
.xxx
.xxxx
D3 D4 D6 为 0(not change) D5 is 1(not change)