EasyManua.ls Logo

General Measure M02 - Page 50

General Measure M02
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M02 Digital Indicator
45
Send command:
STX
Scale no.
Channel No.
C
ZN
Zero millivolt value
CRC
CR
LF
Correct response:
STX
Scale no.
Channel No.
C
ZN
O
K
CRC
CR
LF
Wrong response:
STX
Scale no.
Channel No.
C
ZN
E
Error code
CRC
CR
LF
Here:
ZN——2 bits,5AH4EH
Zero millivolt value——6 bits
For example:
02 30 31 31 43 5A 4E 30 31 32 36 31 30 38 31 0D 0A
Correct response:02 30 31 31 43 5A 4E 4F 4B 33 37 0D 0A
Wrong response:02 30 31 31 43 5A 4E 45 34 30 34 0D 0A(Write data error)
6.2.3.6 Gain calibration
1)With weights
Send command:
STX
Scale no.
Channel No.
C
GY
Weight value
CRC
CR
LF
Correct response:
STX
Scale no.
Channel No.
C
GY
O
K
CRC
CR
LF
Wrong response:
STX
Scale no.
Channel No.
C
GY
E
Error code
CRC
CR
LF