6. Re-install the table insert .
7. Insert the table aligning pin in the hole at
the side of the table.
8. Re-install the extension table and re-attach the
stop-screw
.
Store the miter gauge on the supplied bracket on the
stand as shown.
bottom
view
MITER GAUGE
Attach the power cord brackets to the rear of
the saw, as shown using the 2 Phillips head screws
.
To prevent damage, stow the cord by wrap-
ping it onto the brackets whenever the saw is not
in use.
Remove 4 phillips screws from machine body. Install
the work light and the power cord to the machine
body by using 4 phillips screws and tighten.
The worklight uses a standard 110V household light-
bulb, 60 Watts - Not Included.
INSTALLING POWER CORD STORAGE BRACKETS
ATTACHING THE WORK LIGHT
REMOVING & INSTALLING THE BLADE
Before replacing or adjusting the blade, make sure the switch is in the “OFF” position and that the power cord is unplugged.
1. To remove blade, release blade tension by turning
the blade tension knob counter-clockwise until
it stops.
2. Remove the table insert and table aligning pin.
3. Open upper and lower wheel cover doors.
4. Loosen the 2 Phillips screws and remove the
upper blade guard .
Note: Extension table must be removed when removing/installing the blade. See Step 2 & 8 in INSTALL THE BANDSAW TABLE, pg. 8 & 9.
5.
Remove the blade from the upper and lower
blade guides. Carefully pull the blade from the
side slot and from the wheels
.
6. Swing the left side of the blade toward you, turning
the blade so it will fit through the slot in the table
and remove.