Sec-1.5
Section 1: Critical Installation Information
IMPORTANT INSTALLATION INFORMATION
ENTRAPMENT PROTECTION:
Theinstallationofamonitoredfailsafeexternalreversingdeviceisrequiredonallmomentarycontact
electronicallyoperatedcommercialdoors.Ifsuchareversingdeviceisnotinstalled,theoperatorwill
reverttoaconstantcontactcontrolswitchforcloseoperation.
TheReversingDevicescurrentlyULApprovedare:
• MillerEdge®MEandMTseriesmonitorededgesensorsusedincombinationwithTimer-Close
Module(TCM)P/NOPABTCGX.SorSensingModule(ESM)P/NOPABESX.S
• MillerEdge®MEandMTseriesmonitorededgesensorsusedincombinationwithMillerEdge
InterfaceModuleP/NOPAKMEIGX.S.(DirectconnectthroughSTBinputs.)
• MillerEdge®Wireless(MEL)monitorededgesensorP/NOPAKGMMWE2.S.(Directconnect
throughSTBinputs.)
• ASOSentirGFSeriesMonitoredSensingEdgesusedincombinationwithTimerCloseModule
(TCM)P/NOPABTCGX.SorEdgeSensingModule(ESM)P/NOPABESX.S
• ResidentialSafe-T-Beam®MonitoredPhotocells-P/N37220R(GSTB-BX)andcommercialP/N
38176R.S(includesextensionbrackets).
• SeriesIICommercialSafe-T-Beam®MonitoredPhotocells-P/NOPAKPE2.SandOPAKPEN4GX.S
(NEMA4X).
• MonitoredRetro-ReectivePhotocells-P/NOPGAKRPEN4X.S(NEMA4X).
• MonitoredMillerEdgeLightCurtain-P/NOPAKMLC3.S&OPAKMLC6.S
MonitoredSensingEdgesareavailableinanydoorwidth.
NOTE: DO NOT use take up reels in conjunction with the Monitored Sensing Edge system. Use Coil Cords
Only.