EasyManua.ls Logo

GENMAC OTTO - Troubleshooting Guide - Inverter

GENMAC OTTO
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OTTO 8 in 1 Emergency Kit
16
ENGLISH
TROUBLESHOOTING GUIDE - INVERTER
Trouble Cause Remedy
Lack of power output OTTO battery voltage
below 10 volts
Recharge the OTTO 8 in 1 Emergency Kit
immediately.
Excessive current drawn
by appliance being
operated
Reduce load to maximum of 400 watts.
1. Turn off the device and inverter.
2. Disconnect device.
3. Turn the inverter on and leave running for a
minimum of 2 minutes.
4. Turn off inverter.
5. Quickly plug in device to inverter.
6. Turn on the inverter and the device.
Inverter fuse blown Check and replace if
necessary. Be sure replacement fuse is the
same type and rating.
Inverter Power Indicator
is not lit.
Excessive voltage drop Check OTTO 8 in 1 Emergency Kit and recharge
if voltage drops below 10 volts.
Inverter is overloaded Reduce load to maximum of 400 watts.
Television/Power
Tool will not start
High surge wattage
requirement to start-up
Toggle the Inverter Power Switch on and off in
quick succession a total of 5 times. If the device
does not start, the device is not compatible with
this type of inverter.
Television Interference Picture breaking up
(static)
Place the OTTO 8 in 1 Emergency Kit as far
as possible from the TV, the antenna, and the
coaxial cable.
TV station may be out of range.
Static/noise interference
in audio system
Sound system has weak
alternating current
shielding.
Do not use inverter with low quality audio AC
filtering system.
Replace audio system with high quality noise
filtering.

Table of Contents