EasyManua.ls Logo

GeoMax Zenith35 Pro Series - Batteries: Operation and Charging

GeoMax Zenith35 Pro Series
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
At the Sensor Settings screen the internal radio can be configured with default channel, proto-
col type, channel spacing, transmission power and unit ID. Various required frequencies can be
entered into the channel table and assigned to a specific channel number.
The latest version of the instrument firmware is available from the GeoMax website.
Optional GNSS receiver licences are activated with a key file.
At the Licence Key file screen browse for the key file on your PC and click Upload. A confirma-
tion message is shown once the option has been activated.
4.3 Batteries
4.3.1 Operating Principles
The battery must be charged prior to using it for the first time because it is delivered with
an energy content as low as possible.
The permissible temperature range for charging is between -10°C to +55°C / +14°F to
+ 131°F. For optimal charging we recommend charging the batteries at a low ambient tem-
perature of +10°C to +45°C/ +50°F to 113°F if possible.
It is normal for the battery to become warm during charging. Using the chargers recom-
mended by GeoMax, it is not possible to charge the battery if the temperature is too high.
For new batteries or batteries that have been stored for a long time (> three months), it is
effectual to make only one charge/discharge cycle.
For Li-Ion batteries, a single discharging and charging cycle is sufficient. We recommend
carrying out the process when the battery capacity indicated on the charger or on a Geo-
Max product deviates significantly form the actual battery capacity available.
The batteries can be operated from -20°C to +60°C/-4°F to +140°F.
Low operating temperatures reduce the capacity that can be drawn; high operating temper-
atures reduce the service life of the battery.
4.3.2 Inserting and removing the Battery
010034_001
2
3
0
1
00
34_
001
2
3
1
Sensor firmware
License key
Charging / first-time use
Operation / Discharging
Change battery step-by-
step
24 Operation

Other manuals for GeoMax Zenith35 Pro Series