10. Connect the field controller to the instrument through Bluetooth or through Wi-Fi to
the Zenith35 Pro WebManager.
11. Measure the instrument height using the measuring tape. Refer to "2.6 The Antenna
Reference Plane, ARP" for information on the instrument height.
4.2.2 Setting up as a Post-Processing Base
The following equipment setup is used for static operations over markers.
a Zenith35 Pro instrument
b Battery
c Carrier
d Tribrach
e Tripod
f Field controller
1. Set up the tripod.
2. Mount the tribrach on the tripod.
3. Ensure that the tribrach is over the marker.
4. Mount and level the carrier on the tribrach.
5. Insert the battery into the instrument.
6. Press the ON/OFF button on the instrument for 2 s to switch on the instrument.
7. Screw the instrument onto the carrier.
8. Check that the tribrach and carrier are still level.
9. Connect the field controller to the instrument through Bluetooth or through Wi-Fi to
the Zenith35 Pro WebManager.
10. Measure the instrument height using the measuring tape. Refer to "2.6 The Antenna
Reference Plane, ARP" for information on the instrument height.
4.2.3 Setting Up as a Real-Time Rover
The following equipment setup is used for real-time rover.
Use
Equipment setup -
Zenith35 Pro
Equipment setup step-by-
step
Use
20 Operation