Function lights
Signal Meaning
Constant green Battery is charged / top-up charging
Flashing green Charging
Constant red Charging temperature out of range (battery too hot or too cold)
Flashing red Battery is defective or wrong battery (different manufacturer)
5.4 Battery handling
• Only insert batteries into the charger once they have cooled down.
• GESIPA
®
batteries can be charged approx. 1000 times.
• Do not insert the battery into the charger after each use.
• If battery autonomy becomes signicantly shorter despite proper recharging, the battery
shoukd be replaced.
• Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10°C to 50°C.
GESIPA
®
batteries have a display showing battery life in percent. Press the button in the dis-
play to activate the green LED lights for approx. 5 seconds.
*****
****
***
**
*
Battery full charged
Battery capacity approx. 80%
Battery capacity approx. 60%
Battery capacity approx. 40%
Battery capacity max. 20%, charge soon
5.5 Environmental protection
If batteries need to be replaced, please observe the following:
• Take used GESIPA
®
batteries back to your agent or to GESIPA
®
for recycling.
• Never throw discarded batteries into the waste, into re or into water!