GK-7PLUS CONTROLLER INSTRUCTION MANUAL
12
CALIBRATION PROCESS
ERROR
OK = ACCEPT
Pressing <OK> you will come back to the display of the SUPERVISOR MODE and the calibration factor will
not be modified.
If the new factor has been calculated, once accepted, the display will show the following message:
PROTECT FACTOR?
OK = YES
EXIT = NO
With the affirmative answer, it is achieved the new factor is not altered by a value that can get from a
possible communication of the control software installed in a computer. So the factor value "is protected". If,
on the contrary, it is answered in negative, the factor will be modified by the received communication of the
software. This protection only affects to the described case. It is not valid when a recalibration is made from
the controller.
It is possible to cancel the calibration process pressing the key <EXIT> at any moment. The display will
return to the SUPERVISOR MODE.
3.2.4. Supervisor Mode / CONFIGURATION LIST
This option shows the current kit configuration. A parameter of this configuration, which exactly shows
whether a printer is or is not enabled in the system, will point out where the list will be displayed. If the
printer is enabled, the list will be printed. If, on the contrary, it is not enabled, the configuration will be only
shown on the display.
The system configuration is divided into Console Configuration, Product Configuration, Tank Configuration,
and Hose Configuration, containing each one of these divisions some configuration parameters.
This option does not allow modifying these parameters; these can be only displayed. In the following
section of the SUPERVISOR MODE, SUPERVISOR MENU, each and every one of these parameters can
be modified and explained.
3.2.5. SUPERVISOR mode / SUPERVISOR MENU
This SUPERVISOR MODE section is that really allows the system data contribution and recovery.
This option is not always visible. If the kit is controlled from a computer, this menu will not be accessible to
avoid the possibility of typing data to the system from two different sources, the computer program, and the
own kit keypad. In this case, in this menu position, it will appear the PC DISCONNECTION option. Selecting
it and accepting it, it will appear again the SUPERVISOR MENU.
This menu has the following structure:
SUPERVISOR MENU
CONFIGURATION
CONSOLES
USER IDENTIF.
VEHICLE IDENTIF.
PREDETERMINATION