Closed door
Close the door manually so the door is symmetrical to the door opening. The mechanical end stop
consists of an adjustable angle plate that is adjusted according to the door.
With the door in a closed position, adjust the limit switch so it is activated by the door. The switch's
mounting allows for horizontal adjustment. When adjusting for an open door, make sure that the point of
impact for activated/non-activated switches is distinct and that the breakpoint is not in the switch's outer
area.
Adjusting the restrictor check valve
For smooth operation when opening and closing doors and when locking the threshold lock, use
restrictor check valves. Maneuver the doors manually by having a person hold down the button
to
open or the button to close while another person adjusts by turning the knob on the flow limiter.