GEZE Perlan AUT-NT
9
What to do if...?
What to do if...?8
Problem Cause Remedy
Sliding leaf only opens and
closes slowly
Obstruction on the sliding path Remove obstacle and check sliding leaf for
X
ease of movement.
Floor guide area soiled Disconnect power supply (Emergency-stop
X
switch
or customer-accessible fuse).
Clean oor guide area.
X
Sliding leaf opens and closes
constantly
Obstruction on the sliding path Remove obstruction and check door leaf for
X
ease of movement.
Light beams or reections Check detection eld of motion detector.
X
Objects moving in the eld of detec-
tion of the movement detector(s)
(plants, paper, etc.)
Sliding leaf only opens a crack Obstruction on the sliding path Remove obstruction and check door leaf for
X
ease of movement.
Sliding door does not open Obstruction on the sliding path Remove obstruction and check door leaf for
X
ease of movement.
Movement detector misaligned or
defective
Check the movement detector. If necessary,
X
notify a service technician.
Stop activated Unlock the stop function.
X
Sliding leaf does not close Obstruction on the sliding path Remove obstruction and check door leaf for
X
ease of movement.
Movement detector controls uninter-
ruptedly
Check the movement detector. If necessary,
X
notify a service technician.
No power supply (e.g. power failure) See wiring diagram Perlan AUT-NT,
Mat. No. 139997, Chapter Commissioning