LPS10
- 15 -
V1.0
Command Reply Description
WAL5n…n WAL5;&| Sets to n…n hPa the internal pressure alarm threshold
(800…1100 hPa, default=1100 hPa).
AL5 AL5;n…n| Reads the internal pressure alarm threshold.
All alarm thresholds are integer values with resolution 1 (1 day, 1 °C/°F/K, 1 %RH, 1
hPa).
The alarm condition occurs when the parameter becomes greater than the set thresh-
old.