14. Technical information
• Brass unit 4.25 kg
• PID management of the temperatures
• Separation of the heat sources
• Electronic management of the coffee boiler temperature
• Electronic management of the steam boiler temperature
• Electronic management of the dispensing unit temperature
• Bluetooth interface for total management of the machine including temperatures and counters
• 50 L volumetric pump
• Professional hot water tap and steam wand
• No bottlenecking
15. Safety and functions
• High pressure safety probe for coffee boiler water level
• Safety probe for steam boiler water level
• Tank water level probe
• Dispensing unit temperature probe alarm
• Coffee boiler temperature probe alarm
• Steam boiler temperature probe alarm
• Coffee boiler manual reset safety thermostat
• Steam boiler manual reset safety thermostat
• Unit heating element with thermal-protector
• Management of electric absorption
• Pump time-out
• Armonia Program