Please select the Grid code you need.
Grid Code Setting
6. Operation
User Manual
41
<
Grid Code Setting
Grid Code G59/3
OV-G-V 01
262.2V
OV-G-V-T 01
1.00s
OV-G-V 02
273.7V
OV-G-V-T 02
0.50s
UN-G-V 01
200.1V
UN-G-V-T 01
2.50s
UN-G-V 02
184.0V
UN-G-V-T 02
0.50s
OV-G-F 01
51.50Hz
OV-G-F-T 01
OV-G-F 02
OV-G-F-T 02
UN-G-F 01
UN-G-F-T 01
UN-G-F 02
UN-G-F-T 02
Startup-VH
Startup-VL
90.00s
52.00Hz
0.50s
47.50Hz
20.00s
47.00Hz
0.50s
253.0V
195.5V
Recover-VH
Recover-VL
Startup-FH
Startup-FL
Recover-FH
Recover-FL
Startup-T
Restore-T
10s
10s
253.0V
195.5V
50.50Hz
47.50Hz
50.50Hz
47.50Hz
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>