Bravo pH Monitoring System 37 User Guide
chapter.fm 3/21/16 4:05 pm
5.5 x 7.75 inches (140 mm x 197 mm)
Electromagnetic Compatibility Declaration (EN / IEC 60601-1-2)
This equipment has been tested and found to comply with EN / IEC 60601-1-2.
Compliance with EN / IEC 60601-1-2 shows the equipment is reasonably protected
against harmful interference in a typical medical installation. Tables 1, 2, and 3 apply to
Given Imaging in-line powered and battery-powered external devices.
Caution
Bravo recorder needs special precautions regarding EMC and needs to be
installed and put into service according to the EMC information provided in
the accompanying documents.
Portable and mobile RF communications equipment can affect Bravo
recorder.
The use of accessories, transducers and cables other than those specified,
with the exception of transducers and cables sold by the manufacturer of the
Bravo recorder as replacement parts for internal components, may result in
increased emissions or decreased immunity of the Bravo recorder.
The Bravo recorder should not be used adjacent to or stacked with other
equipment. If adjacent or stacked use is necessary, the Bravo recorder
should be observed to verify normal operation in the configuration in which it
will be used.
Use of accessories, transducers, and cables with the Bravo recorder other
than those specified may result in increased emissions or decreased
immunity of the Bravo recorder.
The Bravo recorder may be interfered with by other equipment, even if that
other equipment complies with CISPR emission requirements.
Table 1. Electromagnetic emissions
Bravo recorder is intended for use in the electromagnetic environment specified below. The customer or
the user of Bravo recorder should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
Non-ionizing
electromagnetic
emissions
CISPR 11
Group 1 (Bravo
pH recorder)
The Bravo recorder uses RF energy only for its internal function. There-
fore, its RF emissions are very low and are not likely to cause any inter-
ference in nearby electronic equipment.
Non-ionizing
electromagnetic
emissions
CISPR 11
Class B (Bravo pH
recorder)
The Bravo recorder is suitable for use in all establishments, including
domestic establishments and those directly connected to the public low-
voltage power supply network that supplies buildings used for domestic
purposes.
Harmonic
emissions
EN 61000-3-2
Not Applicable
(Battery-powered
devices)
Voltage
fluctuations/flicker
emissions EN
61000-3-3
Not Applicable
(Battery-powered
devices)