Page #10 background image
POWER SUPPLY
MODULE
ITNSLP -01
(main and emergency,
automatic change-over)
3
Original cable
2.5m long*
CON7
1
3
1
3
MAIN
SPARE
MAIN
230V AC
SUPPLY
SPARE
230V AC
SUPPLY
L
N
NAVIGATION and SIGNAL
LIGHTS CONTROL,
MAIN UNIT
ITNSL-01T
4
INPUT MODULE FOR FIRST 10 MAIN and 10 SPARE LIGHTS,
ITNL-10
49
50
51
52
53
1
5
9
2
6
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
3
7
4
8
MAIN NAVIGATION
LAMP 1
MAIN NAVIGATION
LAMP 2
MAIN NAVIGATION
LAMP 3
MAIN NAVIGATION
LAMP 4
MAIN NAVIGATION
LAMP 5
MAIN NAVIGATION
LAMP 6
MAIN NAVIGATION
LAMP 7
MAIN NAVIGATION
LAMP 8
MAIN NAVIGATION
LAMP 9
MAIN NAVIGATION
LAMP 10
SPARE NAVIGATION
LAMP 1
SPARE NAVIGATION
LAMP 2
SPARE NAVIGATION
LAMP 3
SPARE NAVIGATION
LAMP 4
SPARE NAVIGATION
LAMP 5
SPARE NAVIGATION
LAMP 6
SPARE NAVIGATION
LAMP 7
SPARE NAVIGATION
LAMP 8
SPARE NAVIGATION
LAMP 9
SPARE NAVIGATION
LAMP 10
L
N
INPUT MODULE
FOR NEXT 3 MAIN
and
3 SPARE LIGHTS,
ITNL-3
49
50
51
52
53
1
5
9
2
6
10
11
12
3
7
4
8
MAIN NAVIGATION
LAMP 1
MAIN NAVIGATION
LAMP 2
MAIN NAVIGATION
LAMP 3
SPARE NAVIGATION
LAMP 1
SPARE NAVIGATION
LAMP 2
SPARE NAVIGATION
LAMP 3
49
50
51
52
53
1
5
9
2
6
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
3
7
4
8
230V AC
supply for lamps
230V AC supply for
lamps to next unit
SIGNAL LAMP 1
SIGNAL LAMP 2
SIGNAL LAMP 3
SIGNAL LAMP 4
SIGNAL LAMP 5
SIGNAL LAMP 6
SIGNAL LAMP 7
SIGNAL LAMP 8
SIGNAL LAMP 9
SIGNAL LAMP 10
SIGNAL LAMP 11
SIGNAL LAMP 12
SIGNAL LAMP 13
INPUT MODULE FOR FIRST 13
SIGNAL LIGHTS,
ITSL-13 (link M1 inserted)
(*check chapter 3.2)
230V AC
supply for lamps
230V AC supply for
lamps to next unit
230V AC
supply for lamps
230V AC supply for
lamps to next unit
SIGNAL LAMP 14
SIGNAL LAMP 15
SIGNAL LAMP 16
SIGNAL LAMP 17
SIGNAL LAMP 18
SIGNAL LAMP 19
SIGNAL LAMP 20
SIGNAL LAMP 21
SIGNAL LAMP 22
SIGNAL LAMP 23
SIGNAL LAMP 24
SIGNAL LAMP 25
SIGNAL LAMP 26
L
N
L
N
L
N
L
N
L
N
Original
cables
1,5m long*
Original
cables
1,5m long*
14
15
NMEA 0183 RECEIVER**
($IIACK sentence)
CON8
CON4
CON5
CON2
CON3
CON2
CON3
CON2
CON3
1
5
9
2
6
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
3
7
4
8
INPUT MODULE FOR NEXT
7 or 13 SIGNAL LIGHTS,
ITSL-7 or ITSL-13 (link M1 removed*)
(*check chapter 3.2)
Original
cables
1,5m long*
CON2
1 pcs of
C.O. voltage-free
output contacts
for external alarm
(power fail, lamps'
circuit fail)
CON3
13
12
11
16
17
18
19
20
Tx-A
Tx-B
-
Rx-A
Rx-B
NMEA 0183
TRANSMITTER**
($IIALR sentence)
Input for N.O.
voltage-free
contact for
external alarm
accept
*Do not route together with power cables
**For NMEA 0183 sentences pls. check appendex 3
Interconncetions between modules
All original cables are cables for communication and
have to be routed in accordance with rules and good
marine practice. Have to be seperated from power
cables which can cause high level of interference.
original
wire
original
wire
49
50
51
52
53
230V AC
supply for lamps
L
N
49
original
wire
original
wire
9
3.1.2 Connection