Inspection and maintenance 10
0020177748_03 ENERGY Installation and maintenance instructions 21
Compare the measured value with the corresponding
value in the table.
Setting the CO value
Great Britain
front casing on / front cas-
ing off
Natural gas
G20
CO at full load
9.2 ±0.2 %
Set for Wobbe index
W
14.09 kWh/m³
O at full load
4.5 ±1.8 vol. %
CO at full load
250 ppm
CO/CO
0.0027
If the setting is not in the specified adjustment range,
you must not start up the product.
Inform Customer Service.
Check whether the requirements regarding air pollution
control and/or CO have been complied with.
Install the front casing.
10.6 Removing the gas-air mixture unit
Note
The gas-air mixture unit consists of three main
components:
Ventilator
Gas valve
Burner cover
1. Switch off the product via the main switch.
2. Close the gas isolator cock.
3. Remove the front casing. ( Page 9)
A
B
1
4. Remove the air intake pipe (1).
D
C
B
2
3
A
5. Remove the screw (2).
6. Push the clip upwards.
7. Remove the flue pipe (3).
A
D
C
B
8. Remove the plug from the gas valve and from the fan.
9. Remove the gas-air mixture unit.
10. Remove both burner seals from the burner cover.
1
11. Remove the burner (4).