Appendix
0020177748_03 ENERGY Installation and maintenance instructions 43
ENERGY 30r -A (H-
GB)
Gas category
I
2H
Diameter of the gas pipe
1/2 inch
Diameter of the heating connec-
tions
3/4 inch
Expansion relief valve connector
(min.)
15 mm
Condensate drain pipework (min.)
21.5 mm
G20 gas supply pressure
2.0 kPa
(20.0 mbar)
Gas flow at P max. hot water
(G20)
3.8 m³/h
Gas flow at P max. heating mode
(G20)
3.2 m³/h
Gas flow at P min. (G20)
0.756 m³/h
CE number (PIN)
CE-0063CP3646
Flue gas mass rate in heating
mode at P min.
3.27 g/s
Flue gas mass rate in heating
mode at P max.
13.8 g/s
Flue gas mass rate in hot water
handling mode at P max.
16.1 g/s
Flue gas temperature (80 °C/60 °C)
at P max.
86
Flue gas temperature (80 °C/60 °C)
at P min.
56
Flue gas temperature (50 °C/30 °C)
at P max.
60
Flue gas temperature (50 °C/30 °C)
at P min.
37
Flue gas temperature in hot water
handling mode
75
Flue gas temperature when over-
heating
104
Nominal efficiency at 50/30 °C
104.0 %
Nominal efficiency at 40/30 °C
106.0 %
NOx class
5
Product dimensions, width
375 mm
Product dimensions, height
602 mm
Net weight
22 kg
Weight when filled with water
27 kg
Technical data Electrics
ENERGY 12r -A (H-GB) ENERGY 15r -A (H-GB) ENERGY 18r -A (H-GB)
Electric connection
230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz
Built-in fuse (slow-blow)
T2/2A, 250V T2/2A, 250V T2/2A, 250V
Max. electrical power consump-
tion
65 W 65 W 66 W
Standby electrical power con-
sumption
2 W 2 W 2 W
Level of protection
IPX4D IPX4D IPX4D
ENERGY 25r -A (H-GB) ENERGY 30r -A (H-GB)
Electric connection
230 V / 50 Hz 230 V / 50 Hz
Built-in fuse (slow-blow)
T2/2A, 250V T2/2A, 250V
Max. electrical power consump-
tion
75 W 60 W