40 Installation and maintenance instructions ENERGY 0020177748_03
J Pipe lengths for the air/flue pipe
J.1 Length L of the C13 type air/flue pipe
Applicability: C13 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C13 type air/flue
pipe
C13 type air/flue
pipe
ENERGY 12r -A
(H-GB)
10 m 25 m
ENERGY 15r -A
(H-GB)
10 m 25 m
ENERGY 18r -A
(H-GB)
10 m 25 m
ENERGY 25r -A
(H-GB)
10 m 25 m
ENERGY 30r -A
(H-GB)
10 m 19 m
J.2 Length L of the C33 type air/flue pipe
Applicability: C33 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C33 type air/flue
pipe
C33 type air/flue
pipe
ENERGY 12r -A
(H-GB)
10 m 25 m
ENERGY 15r -A
(H-GB)
10 m 25 m
ENERGY 18r -A
(H-GB)
10 m 25 m
ENERGY 25r -A
(H-GB)
10 m 25 m
ENERGY 30r -A
(H-GB)
10 m 19 m
J.3 Length L of the C43 type air/flue pipe
Applicability: C43 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C43 type air/flue
pipe
C43 type air/flue
pipe
ENERGY 12r -A
(H-GB)
10 m 10 m
ENERGY 15r -A
(H-GB)
10 m 10 m
ENERGY 18r -A
(H-GB)
10 m 10 m
ENERGY 25r -A
(H-GB)
10 m 10 m
ENERGY 30r -A
(H-GB)
10 m 10 m