EasyManua.ls Logo

Glow-worm ENERGY 30c - K Technical data

Glow-worm ENERGY 30c
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
46 Installation and maintenance instructions ENERGY 0020177746_03
J Pipe lengths for the air/flue pipe
J.1 Length of the C13 type air/flue pipe
Applicability: C13 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C13 type air/flue
pipe
C13 type air/flue
pipe
ENERGY 25c -A
(H-GB)
10 m 25 m
ENERGY 30c -A
(H-GB)
10 m 25 m
ENERGY 35c -A
(H-GB)
10 m 25 m
J.2 Length of the C33 type air/flue pipe
Applicability: C33 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C33 type air/flue
pipe
C33 type air/flue
pipe
ENERGY 25c -A
(H-GB)
10 m 25 m
ENERGY 30c -A
(H-GB)
10 m 25 m
ENERGY 35c -A
(H-GB)
10 m 25 m
J.3 Length of the C43 type air/flue pipe
Applicability: C43 type air/flue pipe
Diameter of the
air/flue pipe
Dia. 60/100 (L)
C43 type air/flue
pipe
ENERGY 25c -A
(H-GB)
5 m
ENERGY 30c -A
(H-GB)
5 m
ENERGY 35c -A
(H-GB)
5 m
K Technical data
Technical data Heating
ENERGY 25c -A (H-
GB)
ENERGY 30c -A (H-
GB)
ENERGY 35c -A (H-
GB)
Max. flow temperature adjustment
range (default setting: 75 °C)
10 80 10 80 10 80
Maximum permissible pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow (ΔT = 20 K)
788 l/h 1,094 l/h 1,102 l/h
Nominal water flow (ΔT = 30 K)
525 l/h 729 l/h 876 l/h

Table of Contents