Supplied By www.heating spares.co Tel. 0161 620 6677
45
Is the power switched on?
Switch the power on
Successful ignition
Check wires between
main PCB and display
PCB
Consult the State Table
Normal operation
Does the display flash 'F'
during or after a CH
demand?
Consult the Fault Table
Is there anything displayed
on the LCD?
Is the display flashing 'F'?
Initiate a CH demand.
Does the boiler light?
Adjust CH setpoint to 82
0
C
and make sure external
control is calling for a
demand. Does the boiler
light?
No No
Yes
Y
es
Yes
Yes
Yes
No
No
No
Yes
START
Yes
No
No
No
13012
Diagram 13.2
CENTRAL HEATING
13 Fault Finding