14
220692C
14
SECTION
t o
Flue and Ventilation
2
t o
step
5
step
1
step
step
16
11
&
t o
step
16
step
6
REAR FLUE APPLICATION
FOLLOW
FLUE INSTALLATION
SIDE FLUE APPLICATION
FOLLOW
FLUE INSTALLATION
Flue Position and
Length
Note. If a longer flue duct is required
DO NOT extend the ducting. A special
long flue system and terminal can be
supplied and MUST be used.
DETERMINE FLUE APPLICATION,
LENGTH, AND TERMINAL
POSITION BEFORE PROCEEDING.
Refer to the relevant diagrams in
Section 4.
For wall thickness of less than 300mm
the boiler can be fully installed from
inside.
For a wall thickness of over 300mm the
cut hole will need to be made good
from the outside.
The rear and side flue assemblies are
designed for internal installation, but
should it be necessary due to
insufficient clearances or boiler
location they can be installed from the
outside.
Rear Flue Lengths
Distance 'R'
S TD 75mm to 692mm
1m 692mm to 1022mm
2m 1022mm to 2022mm
R
2877
Side Flue Lengths
Distance 'S'
S TD 75mm to 692mm
1m 692mm to 1022mm
2m 1022mm to 2022mm
S
2876