INSTALLATION AND SERVICING
EN
4.4.4 Connecting the power input (mains connection)
b
Caution.
Risk of damage from high voltage.
At mains voltages higher than 253 V, electronic
components may be destroyed.
Make sure that the rated voltage of the mains is
230 V.
Disconnect the household power supply before performing the
electrical connection.
Protect the electrical installation by following the guidance
indicated in the “Technical data” chapter.
e
Danger !
The length of the power supply cable must not
exceed 10 metres.
The electrical installation in the dwelling must permit the
power supply to the equipment to be isolated by a double pole
isolation switch and be fused. The double pole isolation switch
must incorporate a gap of 3mm between the contacts.
230V power supply
A
B
C
D
1
5
4
3
2
Key
1 230 V power cable
2 Break out tab
3 Anti-tamper connection
4 Power connection
5 Control unit eBUS
Connect the control unit following the order (A) to (D).
4.4.5 Other connections following the electrical
installation diagram
Consult the system manual for electrical connections following
installation.
Protect access to live parts, attach all cables to the control unit
with anti-tamper connectors.
5 Commissioning
When connected for the rst time, the installation menu is
displayed.
Consult the system manual in order to install and start-up the
system.
5.1 Pairing with wireless outdoor sensor
Consult the outdoor sensor’s installation manual in order to
carry out the operation.
6 User information
After completing the installation:
Explain the system operation to the user.
Draw special attention to the safety instructions which the
user must follow.
Inform the user of the necessity to ensure that the system is
regularly maintained (maintenance contract)..
Answer any questions the user may have.
7 Trouble-shooting
i
The breakdowns described in the system manual
must be handled by a quali ed professional and, if
necessary, by the after-sales department.
7.1 Fault diagnosis
The following checks should be performed before proceeding
onto speci c diagnostics:
- Ensure that it has not been disconnected from the electricity
network and that the control unit is connected correctly.