EasyManuals Logo

Go Power GP-PWM-10-FM User Manual

Go Power GP-PWM-10-FM
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
GP-PWM-10-FM
20
© 2018 Go Power!
It seems like my flooded batteries are losing water over time.
Flooded batteries may need to have distilled water added periodically to
replace fluid loss during charging. Excessive water loss during a short
period of time indicates the possibility of overcharging or aging batteries.
When charging, my flooded batteries are emitting gas.
During charging, hydrogen gas is generated within the battery. The gas
bubbles stir the battery acid, allowing it to receive a fuller state of charge.
Important: Ensure batteries are in a well-ventilated space.
My voltmeter shows a different reading than the GP-PWM-10-FM
display.
The meter value on the GP-PWM-10-FM display is an approximate
reading intended for indication purposes only. There is an approximate
0.1 volt inherent error present that may be accentuated when compared
with readings from another voltmeter.
There may be a slight difference between the battery voltage displayed
on the GP-PWM-10-FM display and the battery voltage measured at the
battery terminals. When troubleshooting using a voltmeter, check both
the battery voltage at the GP-PWM-10-FM controller terminals and
battery voltage at the battery terminals. If a difference of more than 0.5
volts is noted, this indicates a large voltage drop possibly caused by
loose connections, long wire runs, small wire gauge, faulty wiring, a
faulty voltmeter, or all the above. Consult the Suggested Minimum Wire
Gauge chart in Section 5 for wiring suggestions and check all
connections.
What causes a warning signal and when are the warnings
triggered?
Connection
Warning
Notes
LCD
Battery
reverse
polarity
“POL” on LCD
and constant
audible alarm
PV reverse
polarity
“POL” on LCD
and constant
audible alarm
Battery must be
connected with
correct polarity

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power GP-PWM-10-FM and is the answer not in the manual?

Go Power GP-PWM-10-FM Specifications

General IconGeneral
BrandGo Power
ModelGP-PWM-10-FM
CategoryController
LanguageEnglish

Related product manuals