EasyManuals Logo
Home>Go Power>Controller>GP-PWM-10-FM

Go Power GP-PWM-10-FM User Manual

Go Power GP-PWM-10-FM
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
GP-PWM-10-FM
25
© 2018 Go Power!
(3) Modules look dirty, overhead object is shading modules or it is an
overcast day in which a shadow cannot be cast.
Avoid any shading no matter how small. An object as
small as a broomstick held across the solar module may
cause the power output to be reduced. Overcast days
may also decrease the power output of the module.
(4) Disconnect one or both array wires from the controller. Take a
voltage reading between the positive and negative array wire. A single
12-volt module should have an open circuit voltage between 17 and 23
VDC. If you have more than one solar module, you will need to conduct
this test between the positive and negative terminals of each module
junction box with either the positive or the negative wires disconnected
from the terminal.
Remedy:
(2) Reconnect in correct configuration. Tighten all connections. Check
wire gauge and length of wire run. Refer to Suggested Minimum Wire
Gauge in Section 5.
(3) Clean modules, clear obstruction, or wait for conditions to clear.
(4) If the open circuit voltage of a non-connected 12-volt module is lower
than the manufacturer’s specifications, the module may be faulty. Check
for blown diodes in the solar module junction box, which may be shorting
the power output of the module.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power GP-PWM-10-FM and is the answer not in the manual?

Go Power GP-PWM-10-FM Specifications

General IconGeneral
BrandGo Power
ModelGP-PWM-10-FM
CategoryController
LanguageEnglish

Related product manuals