7.2 Setting the Battery Charging Profile
To select the battery charging profile, press and hold the B Button. This
will cause the current battery type to flash.
Then, press the B Button to toggle through the profile options:
Sealed/Gel, AGM/Lithium (LFP) or Flooded.
To confirm the battery profile, press and hold the A Button for 3
seconds.
Non-volatile memory: Any settings made on the GP-PWM-30-SB will
be saved even when the power has been disconnected from the
controller.
Refer to the Battery Charge Profile Chart below for details on each
profile.
7.3 Battery Charging Profile Chart
Battery Type
/GEL
AGM FLOODED LFP
25°C:
Set to 30 minutes every
morning. Applied for 2 hours if
the battery voltage drops
below 12.3 volts.
14.1 VDC
(+/- 0.1V)
14.4 VDC
(+/- 0.1V)
14.4 VDC
(+/- 0.1V)
N/A