19
scanner can store the data while continue-scanning. The scanner will output the data after
the predefined delay elapsed. The maximum storage of data is 1000 characters. If this
parameter is set to be “00”, the scanner will not store data. And if the parameter is set to be
“FF”, the scanner will output data after stopping scanning.
Character encoding system: A character encoding system consists of a code that pairs each
character from a given repertoire. Common examples include Morse code, the Baudot code,
the ASCII and Unicode. If the data received does not display with the proper characters, it
may be because the barcode being scanned was created using a character encoding system
that is different from the one the host program is expecting. Try alternate options to find the
proper one.
Complete data output before next decode attempt: This setting is active only when USB device
type is set as “HID keyboard” or “HID keyboard for Apple Mac”, refer to 3-6 USB interface. If it is
enabled, the scanner will not start next decode attempt until previous data output is completed.