EasyManua.ls Logo

Godox TT685C - Other Protections

Godox TT685C
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Number of flashes that will activate over-temperature protection in high-speed sync triggering mode:
Power Output Times
1/1 15
1/2(+0.3,+0.7) 20
1/4(+0.3,+0.7);
1/8(+0.3,+0.7);
30
1/16(+0.3,+0.7);
1/32(+0.3,+0.7)
40
1/64(+0.3,+0.7);
1/128(+0.3,+0.7)
50
2. Other Protections
The system provides real-time protection to secure the device and your safety. The following lists
prompts for your reference:
Prompts on LCD Panel Meaning
E1 A failure occurs on the recycling system so that the flash cannot fire.
Please restart the flash unit. If the problem still exists, please send this
product to a maintenance center.
E2 The system gets excessive heat. Please allow a rest time of 10 minutes.
E3 The voltage on two outlets of the flash tube is too high. Please send this
product to a maintenance center.
E9 There are some errors occurred during the upgrading process. Please
using the correct firmware upgrade method.