INSTALLATION DIAGRAMS
99
BUS IN
PA PB
BUS OUT
HZ
BUS BUSD
Platea V2Plus
D1L-V2Plus
End of
line
BUS IN
PA PB
BUS OUT
HZ
BUS BUSD
Platea V2Plus
End of
line
*
R.1 20W
Insert a 120 ohm end of
line resistor in the last
distributor.
*
D1L-V2Plus
Sw2
Sw2
Configuring the end of
line in the last monitor.
*
.
V
ideo door entry system with a 1 line distributor and d.c lock release
The installation diagram shows the connection of a video door entry system with one door
panel to access the building, with 1 line distributors and d.c lock release D1L-V2Plus .
100
REMEMBER:
.
Using distributors with one output, the total number of elements in the
installation (monitors or telephones) must never exceed 32 units
Sections chart
RAP-2150
Terminal
SECTIONS CHART
100m.
Door panel-Monitor
P.S. - Door panel
+, -
For greater distances contact our technical
support department.
BUS, D
50m.
Door panel - CV
50m.
2,5mm²
0,5mm²
IMPORTANT: In the output to the monitor/telephone of a
.
distributor cannot be connected
another distributor
SEC
PRI
+
0110230
FA-V2PLUS
- -
+
Main
CV1
+12
CV2
SW1
6
CV1,CV2
2
Core max. electrical resistence to 20ºC
ELECTRICAL CHARACTERISTICS
19,5 W/Km
Nominal capacitance (core-core)
Characteristic impedance
VALUES
CONSTRUCTIVE CHARACTERISTICS
Class V
VALUES
Flexible bare copper conductor of 1mm (twisted)
AP-2150 cable characteristics.
R
45pf/m 10%
100 W 10%
+
-
+
-
Master door panel