WIRING DIAGRAMS
21
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
R
YCON COM
O
W2 ED
HEATPUMP
CONDENSER
CO
W2
RTG
HEATPUMP
ROOM
THERMOSTAT
W2
E
C
Y2R
R
Y2
G
IF NEEDED
HUMIDISTAT
(OPTIONAL)
REMOVE
PRODUCTION
WIRE Y1-O
SEE NOTE 4
NOTES:
1.) Y ENABLES HI SPD FAN COOLING
2.) E ENABLES LO SPD FAN HEATING
W2 ENABLES LO SPD FAN HEATING
W2 AND OT2 CLOSED ENABLES HI SPD
FAN HEATING
3
.) OT2 PJ2 MUST BE CUT FOR THIS
CONFIGURATION
4
.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5
.) DIP SWITCH #4 MUST BE IN THE "OFF" POSITION
HEATPUMP - 2 STG EMHT 2 STG AUX - 1 OUTDOOR T'STAT
1ST STAGE HEATER
Y1
Y1
2ND STAGE HEATER
O
J1
R1
R3
CR10
R2
CR9
PJ6
PJ2
PJ4
OT1
OT2
HUM
12345678
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
CONFIGURATION.
W1 W2
R
YCON COM
O
W2 ED
S
WI
TC
H
DI
P
O
N
O
FF
24 VAC
CR
Y1
W2W1
OUTDOOR
HEATPUMP
CONDENSER
DS1
CR1
CR2
CR5
CR6
CR7
CR8
CR3
CR11
J2 J3
1
4
C2
1
5
Y1RC G Y/Y2OT2 HUM
HUMIDISTAT
OT1
OTCW/W2E\W1
THERMOSTATS
GOODMAN MFG. CO. L.P.
OUTDOOR
THERMOSTAT
1ST STAGE AUX HEAT ENABLED BY ROOM T'STAT
2ND STAGE AUX ENABLED BY ROOM T'STAT AND OUTDOOR T'STAT
R
YCON COM
O
W2 ED
HEATPUMP
CONDENSER
CO
W2
RTG
HEATPUMP
ROOM
THERMOSTAT
W2
ECY2R RY2G
IF NEEDED
HUMIDISTAT
(OPTIONAL)
REMOVE
PRODUCTION
WIRE Y1-O
SEE NOTE 4
NOTES:
1.) Y ENABLES HI SPD FAN COOLING
2.) E ENABLES LO SPD FAN HEATING
W2 AND OT1 CLOSED ENABLES LO SPD FAN HEATING
W2 AND OT2 CLOSED ENABLES HI SPD FAN HEATING
3.) OT1 PJ4 AND OT2 PJ2 MUST BE CUT FOR THIS
CONFIGURATION
4.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5.) DIP SWITCH #4 MUST BE IN THE "
OFF" POSITION
HEATPUMP - 2 STG EMHT 2 STG AUX - 2 OUTDOOR T'STATS
1ST STAGE HEATER
Y1 Y1
2ND STAGE HEATER
O
OT2OT1
J1
R1
R3
CR10
R2
CR9
PJ6
PJ2
PJ4
OT1
OT2
HUM
12345678
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
CONFIGURATION.
W1 W2
R
YCON COM
O
W2 ED
S
WI
TC
H
DI
P
O
N
O
FF
24 VAC
CR
Y1
W2W1
OUTDOOR
HEATPUMP
CONDENSER
DS1
CR1
CR2
CR5
CR6
CR7
CR8
CR3
CR11
J2 J3
1
4
C2
1
5
Y1RC G Y/Y2OT2 HUM
HUMIDISTAT
OT1
OTCW/W2E\W1
THERMOSTATS
GOODMAN MFG. CO. L.P.
NO AUX HEAT IN HEATPUMP MODE UNTIL OUTDOOR T'STAT CLOSES
OT1 OT2OTC
OUTDOOR