Important Safety Instructions
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owner’s and installer’s responsibility to read and comply
with all safety information and instructions accompanying these
symbols. Failure to heed safety information increases the risk
of personal injury, property damage, and/or product damage.
HIGH VOLTAGE!
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage,
personal injury or death.
Goodman will not be responsible for any injury or
property damage arising from improper service or
service procedures. If you perform service on your
own product, you assume responsibility for any
personal injury or property damage which may result.
INSTALLATION & OPERATIONS MANUAL
SPLIT TYPE ROOM AIR CONDITIONER AND HEAT PUMP MODELS
MSC/MSH 9,000 & 12,000 BTUH • 115 VOLT
© 2011 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com -or- www.amana-hac.com
IO-411
August 2011
To prevent the risk of property damage, personal injury, or
death, do not store combustible materials or use gasoline
or other flammable liquids or vapors in the vicinity of thi
appliance.
To prevent heat releated illness or death, do not use this
device for unattended cooling of persons or animals unable
to react to product failure. Failure of unattended air
conditioner may result in extreme heat in area intended
for cooling, causing heat-related illness or death of
persons or animals.
Shipping Inspection
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and subse-
quent investigation is the responsibility of the carrier. Verify
the model number, specifications, electrical characteristics,
and accessories are correct prior to installation. The distribu-
tor or manufacturer will not accept claims from dealers for trans-
portation damage or installation of incorrectly shipped units.
O
Question and Answer IconNeed help?

Do you have a question about the Goodman MSH 9,000 and is the answer not in the manual?

Goodman MSH 9,000 Specifications

General IconGeneral
BTU9, 000
Refrigerant TypeR-410A
Phase1
Cooling Capacity9, 000 BTU
Operating Voltage208/230V

Summary

Important Safety Instructions

General Safety Warnings

Covers high voltage, combustible materials, and unattended cooling risks.

Service Responsibility Warning

Disclaimer on responsibility for injury due to improper service.

Shipping Inspection

Codes & Regulations Compliance

Installation Site Considerations

Indoor Unit Mounting Clearance

Indoor unit mounting requirement for clearance from floor/grade.

Electrical Connection Caution

Warning against using extension cords for the unit.

Outdoor Unit Placement Guidelines

Outdoor unit placement considerations for airflow and environment.

Rooftop Installation Considerations

Required Tools List

Indoor Unit Mounting Bracket Installation

Piping and Drain Hose Installation

Drain Hose Installation Guidelines

Guidelines for installing the drain hose to ensure proper condensate drainage.

Refrigerant Piping Installation Types

Procedures for connecting refrigerant piping, including left, right, and rear configurations.

Indoor Unit Mounting and Piping

Routing and Securing Indoor Unit Piping

Passing and bundling refrigerant lines, cables, and drain hoses through the wall.

Securing the Indoor Unit

Securing the indoor unit onto the wall bracket for stability and proper operation.

Outdoor Unit Installation Precautions

Outdoor Unit Placement and Anchoring

Guidelines for outdoor unit placement to ensure optimal performance and longevity.

Drain Joint Installation Methods

Drain Joint Installation with Seals

Procedure for installing drain joints that include seals.

Drain Joint Installation without Seals

Procedure for installing drain joints that do not include seals.

Refrigerant Flare Connection Procedure

Refrigerant Flare Connection Steps

Tube Preparation for Flaring

Preparing copper tubing using a flare tool and specific measurements.

Flare Connection Tightening

Securing flare connections using torque specifications for leak prevention.

Electrical Installation Safety

Technician Qualification and High Voltage Warnings

Requirement for qualified technicians and high voltage safety precautions.

Indoor Unit Cable Connection

Outdoor Unit Cable Connection

Leak Testing and System Evacuation

Leak Testing Procedure

Method for testing the system for refrigerant leaks using pressure and soapy water or a detector.

System Evacuation Procedure

Process of removing air and moisture from the system using a vacuum pump.

Safe Refrigerant Handling

Refrigerant Handling & Cylinder Safety

Critical safety warnings for handling refrigerants and refrigerant cylinders.

Electrical Safety Checks

Test Running Procedure

Related product manuals