EasyManua.ls Logo

Goodwe GW10K-MS

Goodwe GW10K-MS
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
User Manual V1.1-2022-11-15
10 Technical Parameters
AC Connector AC Connector
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DC II / AC III
Protective Class I
The Decisive Voltage Class (DVC) PV: C AC: C Com: A
Active Anti-islanding Method AFDPF + AQDPF
*4
Country of Manufacture (Only for
Australia)
China
Technical Data GW8500-MS GW10K-MS
Input
Max. Input Power (W) 13,500 13,500
Max. Input Voltage (V) 600 600
MPPT Operating Voltage Range (V) 80~550 80~550
MPPT Voltage Range at Nominal Power
(V)
250~500 280~500
Start-up Voltage (V) 80 80
Nominal Input Voltage (V) 360 360
Max. Input Current per MPPT (A) 16 16
Max. Short Circuit Current per MPPT (A) 20 20
Max. Backfeed Current to The Array (A) 0 0
Number of MPP Trackers 3 3
Number of Strings per MPPT 1 1
Output
Nominal Output Power (W) 8500 10000
Nominal Output Apparent Power (VA) 8500 10000
Max. AC Active Power (W)
*1
9350 10000
Max. AC Apparent Power (VA)
*2
9350 10000
Nominal Power at 40℃ (W) (Only for
Brazil)
8500 10000
Max Power at 40℃ (Including AC
Overload) (W) (Only for Brazil)
9350 10000
Nominal Output Voltage (V) 220/230/240 220/230/240
Output Voltage Range (V) 180~265 180~265
Nominal AC Grid Frequency (Hz) 50/60 50/60
AC Grid Frequency Range (Hz) 45~55 / 55~65 45~55 / 55~65