42
User Manual V1.1-2022-11-15
10 Technical Parameters
Max. Output Current (A) 42.5 45.5
Max. Output Fault Current (Peak and
Duration) (A)(at 5ms)
90 90
Inrush Current (Peak and Duration) (A)
(at 50μ s)
150 150
Nominal Output Current (A) 37 43.5
Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion <3%
Maximum Output Overcurrent
Protection (A)
78 78
Eciency
Max. Eciency 97.7% 97.7%
European Eciency 97.3% 97.3%
Protection
PV Insulation Resistance Detection Integrated
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Anti-islanding Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch Integrated
DC Surge Protection Type II
AC Surge Protection Type III (Type II Optional)
AFCI Optional
Emergency Power O Optional
Remote Shutdown Optional
General Data
Operating Temperature Range (℃) -25~+60
Relative Humidity 0~100%
Max. Operating Altitude (m)
*3
4000
Cooling Method Natural Convection
User Interface LED, LCD
Communication WiFi, RS485 or LAN (Optional)
Communication Protocols Modbus-RTU (SunSpec Compliant)
Weight (kg) 22.5
Dimension (W×H×D mm) 415×511×175