44
User Manual V1.1-2022-11-15
10 Technical Parameters
Max Power at 40℃ (Including AC Overload)
(W) (Only for Brazil)
7700
Nominal Output Voltage (V) 220
Output Voltage Range (V) 176~242
Nominal AC Grid Frequency (Hz) 60
AC Grid Frequency Range (Hz) 55~65
Max. Output Current (A) 35.0
Max. Output Fault Current (Peak and
Duration) (A)(at 5ms)
74
Inrush Current (Peak and Duration) (A)(at 50μ
s)
150
Nominal Output Current (A) 31.8
Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion <3%
Maximum Output Overcurrent Protection (A) NA
Eciency
Max. Eciency 97.7%
European Eciency 97.3%
Protection
PV Insulation Resistance Detection Integrated
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Anti-islanding Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch Integrated
DC Surge Protection Type III
AC Surge Protection Type III
AFCI Optional
Remote Shutdown Optional
General Data
Operating Temperature Range (℃) -25~+60
Relative Humidity 0~100%
Max. Operating Altitude (m)
*3
4000
Cooling Method Natural Convection