45
User Manual V1.1-2022-11-15
11 Appendix
User Interface LED, LCD
Communication WiFi, RS485 or LAN (Optional)
Communication Protocols Modbus-RTU (SunSpec Compliant)
Weight (kg) 22.5
Dimension (W×H×D mm) 415×511×175
Noise Emission (dB) < 30
Topology Non-isolated
Self-consumption at Night (W) <1
Ingress Protection Rating IP65
Anti-corrosion Class C4
DC Connector MC4 (4-6 mm²)
AC Connector AC Connector
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DC II / AC III
Protective Class I
The Decisive Voltage Class (DVC) PV: C AC: C Com: A
Active Anti-islanding Method AFDPF + AQDPF
*4
Country of Manufacture (Only for Australia) China
*1. For Belgium Max. AC Active Power (W): GW5000-MS is 5000, GW6000-MS is 6000, GW7000-MS
is 7000, GW8500-MS is 8500, GW10K-MS is 10000.
*2. For Belgium Max.Output Apparent Power (VA): GW5000-MS is 5000, GW6000-MS is 6000,
GW7000-MS is 7000, GW8500-MS is 8500, GW10K-MS is 10000.
*3. For Australia Max. Operating Altitude (m) is 3000.
*4. AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with Positive
Feedback.

Other manuals for Goodwe GW10K-MS