What does IFan Fail mean on my Goodwe GW8000-SDT-20?
- Ccharles10Sep 23, 2025
An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
What does IFan Fail mean on my Goodwe GW8000-SDT-20?
An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
How to fix an 'Over Temperature' error on my Goodwe GW8000-SDT-20 Inverter?
If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
What to do if my Goodwe Inverter displays 'Isolation Fail'?
If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
What does 'Vac Fail' mean on my Goodwe Inverter?
If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
What causes 'Fac Fail' on a Goodwe GW8000-SDT-20 Inverter?
If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
What does ARC Fault mean on a Goodwe Inverter, and how do I fix it?
An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
What should I do if my Goodwe Inverter displays a PV Over Voltage error?
A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
Why does my Goodwe GW8000-SDT-20 show a Fac Fail error?
A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
What does 'IFan Fail' mean on my Goodwe Inverter?
If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
What does 'DC Bus High' mean on my Goodwe Inverter?
If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.
General safety rules and recommendations for safe operation and installation.
Safety precautions specific to the DC input side of the inverter.
Safety precautions specific to the AC output side of the inverter.
Safety warnings and guidelines related to the physical installation of the inverter.
Specifies environmental conditions and mounting support requirements for inverter installation.
Detailed instructions for mounting the inverter onto its support structure.
Crucial safety warnings and precautions before making electrical connections.
Instructions for properly connecting the protective earth (PE) cable.
Detailed steps for connecting the DC input cables from the PV array.
Guidelines for connecting the AC output cable to the grid.
Steps to safely turn on the inverter and connect it to the grid and battery.
Steps for safely shutting down the inverter before performing maintenance.
Methods for diagnosing and resolving common inverter faults and issues.
General safety rules and recommendations for safe operation and installation.
Safety precautions specific to the DC input side of the inverter.
Safety precautions specific to the AC output side of the inverter.
Safety warnings and guidelines related to the physical installation of the inverter.
Specifies environmental conditions and mounting support requirements for inverter installation.
Detailed instructions for mounting the inverter onto its support structure.
Crucial safety warnings and precautions before making electrical connections.
Instructions for properly connecting the protective earth (PE) cable.
Detailed steps for connecting the DC input cables from the PV array.
Guidelines for connecting the AC output cable to the grid.
Steps to safely turn on the inverter and connect it to the grid and battery.
Steps for safely shutting down the inverter before performing maintenance.
Methods for diagnosing and resolving common inverter faults and issues.
| Rated Output Power | 8000 W |
|---|---|
| Max. DC Power | 10400 W |
| Max. PV Input Power | 10400 W |
| Max DC Input Voltage | 1000 V |
| Max. PV Input Voltage | 1000 V |
| Number of MPPT Trackers | 2 |
| Max DC Input Current per MPPT | 13 A |
| Rated AC Power | 8000 W |
| Max. AC Power | 8800 W |
| AC Voltage Range | 180 - 280 V |
| THDi | <3% |
| AC Grid Frequency | 50 / 60 Hz |
| Max. Efficiency | 98.3% |
| MPPT Efficiency | 99.9% |
| Protection Degree | IP65 |
| Cooling Concept | Natural Convection |
| AC Output Frequency | 50 / 60 Hz |
| Peak Efficiency | 98.3% |
| Cooling Method | Natural Convection |
| Protection Level | IP65 |
| MPPT Voltage Range | 200 - 850 V |
| Rated AC Voltage | 230 V / 400 V |
| Power Factor | 0.8 leading - 0.8 lagging |
| Operating Temperature Range | -25°C to 60°C |
| AC Output Voltage | 230 V / 400 V |