ISO Failure
Error Code: 14
Cause: Inverter detects ground insulation impedance is too low
Measurement:
A. Check the time when inverter goes fault, if it is at dawn/ dusk or rainy days. Please ignore
this fault. As the humidity goes high, the impedance will become low, which will lead to
ISO failure;
B. Measure the impedance of PV+ & PV- to ground, the values should be higher than 2MΩ. If
the impedance is too low, please check the insulation, or rewiring the PV connection;
C. Measure the impedance of N to ground, the value should close to zero. If not, please
check the AC wiring.
D. Check if the firmware version of the inverter is the latest. As with the time goes, threshold
in the firmware are also changing. If not the latest, please update the firmware;
E. If all above don’t work, please contact with GoodWe local service center.
2.4 Trouble Shooting

Other manuals for Goodwe NS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe NS Series and is the answer not in the manual?

Goodwe NS Series Specifications

General IconGeneral
Protection DegreeIP65
Number of MPP Trackers2
CoolingNatural Convection
Power Range3kW to 6kW
MPPTDual MPPT
CommunicationWiFi
MPPT Voltage Range120-500V
Nominal AC Output Power3000W to 6000W
Max. AC Output Power3.3kW, 4kW, 4.6kW, 5.5kW, 6.6kW
Nominal Output Voltage230V
Operating Temperature Range-25 ~ +60 °C
Output Power3000W to 6000W
MPPT Range120-500V
Output Voltage230V
Frequency50/60 Hz

Related product manuals