Relay Check Failure
Error Code: 07
Cause: Output relay fault
Measurement:
A. Switch on AC & DC power of the inverter, listen to the inverter when inverter is checking. If
there is no relay clicking sound, please contact with GoodWe local service center.
2.4 Trouble Shooting

Other manuals for Goodwe NS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe NS Series and is the answer not in the manual?

Goodwe NS Series Specifications

General IconGeneral
Protection DegreeIP65
Number of MPP Trackers2
CoolingNatural Convection
Power Range3kW to 6kW
MPPTDual MPPT
CommunicationWiFi
MPPT Voltage Range120-500V
Nominal AC Output Power3000W to 6000W
Max. AC Output Power3.3kW, 4kW, 4.6kW, 5.5kW, 6.6kW
Nominal Output Voltage230V
Operating Temperature Range-25 ~ +60 °C
Output Power3000W to 6000W
MPPT Range120-500V
Output Voltage230V
Frequency50/60 Hz