EasyManua.ls Logo

Goodwe NS Series - 3.1.1 NS Series Certifications and General Data

Goodwe NS Series
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© copy right reserved by GoodWe
Certifications
& Standards
Residual
current monitoring unit
Integrated
Anti
-islanding protection
Integrated
DC
switch
Integrated (Optional)
AC
over current protection
Integrated
Insulation
monitoring
Integrated
Grid
regulation
G83/2, VDE0126-1-1,AS4777.2&.3,
EN50438, ERDF-NOL-RES_13E;
Safety
IEC62109-1&-2, AS3100
EMC
EN61000-6-1, EN61000-6-2, EN61000-6-3
EN61000-6-4, EN61000-3-2, EN61000-3-3
General Data
Dimensions
(WxHxD)
344*274.5*128
Weight
(kg)
7.5 8.5
Mounting
Wall Bracket
Ambient
temperature range
-25~60
(Over 45
Derating)
Relative
humidity
0~95%
Max
. operating altitude
4000m (Over 2000m Derating)
Protection
degree
IP65
Topology
Transformerless
Night
power consumption(W)
<1
Cooling
Natural Convection
Noise
emision(dB)
<25
Display
LCD
Communication
RS485/WiFi
Standard
warranty(years)
5/10/15/20/25 (Optional)
3.1 Technical Data NS Series

Other manuals for Goodwe NS Series